Safety Monitoring Relays
SR103AM
Dual-Channel Safety Monitoring Relay.
◇ Power requirements—the SR103AM SR103AM datasheet PDF SR103AM will accept 24 VAC/DC or 115 VAC.
◇ Inputs—the SR103AM
SR103AM SR103AM PDF SR103AM datasheet will accept single or dual N/C inputs or dual inputs SR103AM PDF from a light curtain.
◇ Outputs—the SR103AM has 3 N/O outputs to route power to the coils of power contactors, plus 1 N/C auxiliary output for signaling purposes.
◇ External Device Monitoring (EDM) is provided with a N/C loop between S11/S12 and S21 on the SR103AM.
◇ Monitored manual or automatic/manual reset modes are available on the SR103AM. Monitored manual reset requires closure of the reset circuit followed by opening of the circuit. Reset occurs when circuit is opened. Auto reset requires only closure of the reset circuit as reset occurs when circuit iis SR103AM datasheet closed.