Home >> Products >> 41
OMRON Data memory expansion unit CV1000-DM641
Model : CV1000-DM641.
Available CV1000/2000/CVM1-CPU21-V2.
64K words.
ABB Inverter ACS800-01-0050-2
Product Name: Inverter.
Model: ACS800-01-0050-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 141A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 164A.
Typical motor power in no-overload use: 37KW
Frame size: R6.
Typical motor power in light-overload use: 37Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 97A.
Typical motor power in heavy-duty use: 30KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 132A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-2
Product Name: Inverter.
Model: ACS800-01-0070-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Frame size: R6.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
Typical motor power in no-overload use: 55KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 184A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
Typical motor power in heavy-duty use: 37KW.
Rated current available continuously without overloadability at 40 °C: 202A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0003-3
Product Name: Inverter.
Model: ACS800-01-0003-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 5.1A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 1.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
Typical motor power in light-overload use: 1.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
Typical motor power in heavy-duty use: 1.1KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0011-3
Product Name: Inverter.
Model: ACS800-01-0011-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 19A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 24A.
Typical motor power in no-overload use: 7.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 18A.
Typical motor power in light-overload use: 7.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 14A.
Typical motor power in heavy-duty use: 5.5KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-3
Product Name: Inverter.
Model: ACS800-01-0030-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 55A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
Typical motor power in no-overload use: 30KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 50A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 37A.
Typical motor power in heavy-duty use: 18.5KW.
Frame size: R4.
Typical motor power in light-overload use: 22Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes Cepex panel mounted receptacle 4114
Product Name:Cepex panel mounted receptacle
Part No.:4114.
Ampere:16A.
Poles:4p.
Voltage:500V.
Earth position: 7h.
Hertz 50-60Hz.
Protection type IP44.
screw terminals.
also suitable for installation in cable ducts and columns.
meeting DIN 18032 standards for ball rebound.
Mennekes Cepex panel mounted receptacle 4119
Product Name:Cepex panel mounted receptacle
Part No.:4119.
Ampere:32A.
Poles:4p.
Voltage:500V.
Earth position: 7h.
Hertz 50-60Hz.
Protection type IP44.
screw terminals.
also suitable for installation in cable ducts and columns.
meeting DIN 18032 standards for ball rebound.
Mennekes Cepex panel mounted receptacle 4145
Product Name:Cepex panel mounted receptacle
Part No.:4143.
Ampere:16A.
Poles:4p.
Voltage:400V.
Earth position: 6h.
Hertz 50-60Hz.
Protection type IP44.
scscrew terminals.
with labelling field.
suitable for installation in cable ducts and columns.
Mennekes Cepex panel mounted receptacle 4150
Product Name:Cepex panel mounted receptacle
Part No.:4150.
Ampere:32A.
Poles:5p.
Voltage:400V.
Earth position: 6h.
Hertz 50-60Hz.
Protection type IP44.
scscrew terminals.
with labelling field.
suitable for installation in cable ducts and columns.
Mennekes Cepex panel mounted receptacle 4172
Product Name:Cepex panel mounted receptacle
Part No.:4172.
Ampere:16A.
Poles:3p.
Voltage:230V.
Earth position: 6h.
Hertz 50-60Hz.
Protection type IP44.
screw terminals.
with labelling field.
with safety lock.
two keys.
cannot be dismantled when locked.
on request with identical locks.
suitable for installation in cable ducts and columns.
with identical lock: part no. + index G.
392 Results 12/Page Page 31 of 33     [First Page] << Previous 27 28 29 30 31 32 33 Next >>