OMRON Group-2 B7A Interface Module C200H-B7A21
Model: C200H-B7A21.
I/O points: 16 output points and 16 input points or 15 input points + 1 error
input.
Weight: 300g max.
OMRON B7A Interface Module CQM1-B7A21
Product name: B7A Interface Module.
Model: CQM1-B7A21.
Specification: 16 input points, 16 output points.
OMRON Adapter CV500-CIF21
Model : CV500-CIF21.
When connected to form C500-NC222.
OMRON ID Sensor Unit C500-IDS21
C500-ID Special I/O Unit ID Sensor Unit General Purpose C500-IDS21.
OMRON Data memory expansion unit CV1000-DM641
Model : CV1000-DM641.
Available CV1000/2000/CVM1-CPU21-V2.
64K words.
OMRON Data memory expansion unit CV1000-DM251
Model : CV1000-DM251.
Available CV1000/2000/CVM1-CPU21-V2.
256K words.
Mitsubishi CPU A2NCPU
Model: A2NCPU.
I/O points: 512 points.
Program capacity: 14k steps.
Basic instruction processing speed: 1.0us.
Memory: Memory-minute cassette inserted.
Size: 254(H)×79.5(W)×121(D)mm.
Weight: 0.62kg.
ABB Inverter ACS800-01-0120-7
Product Name: Inverter.
Model: ACS800-01-0120-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 113A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 172A.
Typical motor power in no-overload use: 110KW
Frame size: R6.
Typical motor power in light-overload use: 90Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 86A.
Typical motor power in heavy-duty use: 75KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 108A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0175-7
Product Name: Inverter.
Model: ACS800-01-0175-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 166A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 131A.
Typical motor power in heavy-duty use: 110KW.
Typical motor power in light-overload use: 132Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Frame size: R6.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.