Home >> Products >> ABB >> Inverter >> ACS355 Inverter >> ACS355-03X-07A5-2 Current rating represents the rated continuous drive output current inside the drive specification. ABB ACS355-03X-07A5-2

ACS355-03X-07A5-2 Current rating represents the rated continuous drive output current inside the drive specification. ABB ACS355-03X-07A5-2

Product Name: Inverter.
Model: ACS355-03X-07A5-2.
3-phase ACS355-03X-07A5-2 AC supply, 200 to 240 V.
Typical motor ACS355-03X-07A5-2 power in 400 V at normal use: 1.5kw.
Typical motor power in 460 V at normal use: 2.0hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 7.5A.
This code states the factory installed SW variants to the drive.
ABB ACS355-03X-07A5-2
Product Name: Inverter.
Model: ACS355-03X-09A8-2.
Current rating represents ABB ACS355-03X-07A5-2 the rated continuous drive output current inside the drive specification.
Typical motor power in 400 ABB ACS355-03X-07A5-2 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3.0hp.
Continuous ABB ACS355-03X-07A5-2 rms current. 50% overload is allowed for one minute in ten minutes: 9.8A.
Frame size: R2.
3-phase AC supply, 200 to 240 V.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.

Product Name: Inverter.
Model: ACS355-03X-03A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 1.1kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 1.5hp.

Product Name: Inverter.
Model: ACS355-03X-07A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 3.0kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 7.3A.
Frame size: R1.
Typical motor power in 460 V at normal use: 3.0hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.

Product Name: Inverter.
Model: ACS355-03X-03A5-2.
Current rating represents the rated continuous drive output current inside the drive specification.
Typical motor power in 400 V at normal use: 0.55kw.
Typical motor power in 460 V at normal use: 0.75hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.5A.
Frame size: R0.
3-phase AC supply, 200 to 240 V.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code sttates ACS355-03X-07A5-2 the factory installed SW variants to the drive.