Home >> Products >> ABB >> Inverter >> ACS550 Inverter >> ACS550-01-05A4-4 Wall-mounted units. ABB ACS550-01-05A4-4 Inverter

ACS550-01-05A4-4 Wall-mounted units. ABB ACS550-01-05A4-4 Inverter

Product Name: Inverter.
Model: ACS550-01-05A4-4.
3-phase ACS550-01-05A4-4 supply voltage 380 to 480 V.
Continuous rms current. 10% ACS550-01-05A4-4 overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3hp.
Wall-mounted units.
Typical motor power in 400 V at heavy-duty use: 1.5KW.
Typical motor power in 460 V at heavy-duty use: 2HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.
ABB ACS550-01-05A4-4
Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage ABB ACS550-01-05A4-4 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous ABB ACS550-01-05A4-4 rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous ABB ACS550-01-05A4-4 rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-08A8-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 6.9A
Typical motor power in 460 V at normal use: 5.4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 8.8A.
Typical motor power in 400 V at heavy-duty use: 3KW.
Typical motor power in 460 V at heavy-duty use: 4HP.
Typical motor power in 400 V at normal use: 4kw..
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-06A9-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 6.9A.
Typical motor power in 400 V at heavy-duty use: 2.2KW.
Typical motor power in 460 V at heavy-duty use: 3HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 3kw.

Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for ACS550-01-05A4-4 one minute in ten minutes: 15.4A.
Frame size: R2.





...More Related Model >>>>

Related Download
Related Models