Home >> Products >> ABB >> Inverter >> ACS550 Inverter >> ACS550-01-072A-4 3-phase supply voltage 380 to 480 V. ABB ACS550-01-072A-4

ACS550-01-072A-4 3-phase supply voltage 380 to 480 V. ABB ACS550-01-072A-4

Product Name: Inverter.
Model: ACS550-01-072A-4.
3-phase ACS550-01-072A-4 supply voltage 380 to 480 V.
Typical motor ACS550-01-072A-4 power in 400 V at heavy-duty use: 30KW.
Typical motor power in 400 V at normal use: 37kw.
Typical motor power in 460 V at normal use: 50hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 72A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 40HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 59A.
Frame size: R4.
ABB ACS550-01-072A-4
Product Name: Inverter.
Model: ACS550-01-08A8-4.
3-phase supply voltage ABB ACS550-01-072A-4 380 to 480 V.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ABB ACS550-01-072A-4 ten minutes: 6.9A
Typical motor power in 460 V at normal use: 5.4hp.
Continuous ABB ACS550-01-072A-4 rms current. 10% overload is allowed for one minute in ten minutes: 8.8A.
Typical motor power in 400 V at heavy-duty use: 3KW.
Typical motor power in 460 V at heavy-duty use: 4HP.
Typical motor power in 400 V at normal use: 4kw..
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.

Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-06A9-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 6.9A.
Typical motor power in 400 V at heavy-duty use: 2.2KW.
Typical motor power in 460 V at heavy-duty use: 3HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.4A..
Typical ACS550-01-072A-4 motor power in 400 V at normal use: 3kw.





...More Related Model >>>>