Home >> Products >> ABB >> Inverter >> ACS800 Inverter >> ACS800-01-0060-2 Continuous current allowing 1 Ihd for 1 min / 5 min at 40 115A. ABB ACS800-01-0060-2

ACS800-01-0060-2 Continuous current allowing 1 Ihd for 1 min / 5 min at 40 115A. ABB ACS800-01-0060-2

Product Name: Inverter.
Model: ACS800-01-0060-2.
UN ACS800-01-0060-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0060-2 nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 166A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
Typical motor power in no-overload use: 45KW
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 115A.
Typical motor power in heavy-duty use: 30KW.
Frame size: R6.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
ABB ACS800-01-0060-2
Product Name: Inverter.
Model: ACS800-01-0025-3.
UN = 400 V (Range 380 to ABB ACS800-01-0060-2 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without ABB ACS800-01-0060-2 overloadability at 40 掳C: 44A.
Maximum output current. Available for 10 s at start, ABB ACS800-01-0060-2 otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 41A.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 32A.
Typical motor power in heavy-duty use: 15KW.
Typical motor power in no-overload use: 22KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0009-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 25A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 5.5KW
Frame size: R3.
Typical motor power in light-overload use: 5.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 19A.
Typical motor power in heavy-duty use: 4KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 24A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0004-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 掳C: 6.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 5.9A.
Typical motor power in light-overload use: 2.2Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 1.3A.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 uunits, ACS800-01-0060-2 H1 is 994 mm, depth 424 mm and weight is 80 kg.