ABB Inverter ACS800-01-0006-5
Product Name: Inverter.
Model: ACS800-01-0006-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 8.1A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.6A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 3KW.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-3
Product Name: Inverter.
Model: ACS800-01-0020-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 34A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 15KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
Typical motor power in heavy-duty use: 11KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS550-01-038A-4
Product Name: Inverter.
Model: ACS550-01-038A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 15KW.
Typical motor power in 400 V at normal use: 18.5kw.
Typical motor power in 460 V at normal use: 25hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 38A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 20HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31A.
Frame size: R3.
ABB Inverter ACS355-03X-46A2-2
Product Name: Inverter.
Model: ACS355-03X-46A2-2.
3-phase AC supply, 200 to 240 V.
Frame size: R4.
Typical motor power in 460 V at normal use: 15.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 46.2A.
Typical motor power in 400 V at normal use: 11.0kw.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-04A1-4
Product Name: Inverter.
Model: ACS355-03X-04A1-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 1.5kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 2.0hp.
Mennekes Connector AM-TOP 2255
Product Name:Connector AM-TOP?
Part No.2255.
Ampere :32A.
Poles:7P.
Voltage:400V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology:Screw terminals.
Contact:nickel plated contacts, highly heat resistant contact carrier.
Protection type:IP67.
screw terminals.
with highly heat resistant contact carrier.
nickel plated contacts.
single part body.
cable gland and sealing.
strain relief and protection against kinking.
ABB Inverter ACS355-01X-04A7-2
Product Name: Inverter.
Model: ACS355-01X-04A7-2.
Frame size: R1.
Typical motor power in 400 V at normal use: 0.75kw.
Typical motor power in 460 V at normal use: 1.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.7A.
1-phase AC supply, 200 to 240 V.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS550-01-045A-4
Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.