ACS550-01-045A-4 ABB ACS550-01-045A-4 Inverter

Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase ACS550-01-045A-4 supply voltage 380 to 480 V.
Wall-mounted units.
Typical ACS550-01-045A-4 motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.
ABB ACS550-01-045A-4
Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage ABB ACS550-01-045A-4 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal ABB ACS550-01-045A-4 use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms ABB ACS550-01-045A-4 current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical Inverter motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous Inverter rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.

Product Inverter Name: Inverter.
Model: ACS550-01-03A3-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 1.5hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 3.3A.
Typical motor power in 400 V at heavy-duty use: 0.75KW.
Typical motor power in 460 V at heavy-duty use: 1HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Typical motor power in 400 V at normal use: 1.1kw.

Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 15.4A.

Product Name: Inverter.
Model: ACS550-01-08A8-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 6.9A
Typical motor power in 460 V at normal use: 5.4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 8.8A.
Typical motor power in 400 V at heavy-duty use: 3KW.
Typical motor power in 460 V at heavy-duty use: 4HP.
Typical motor ppower ABB ACS550-01-045A-4 in 400 V at normal use: 4kw..
Frame size: R1.