ABB Inverter ACS550-01-012A-4
Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.
ABB Inverter ACS800-01-0205-5
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Inverter FR-F740-S355K
Product Name: Inverter.
Model: FR-F740-S355K.
355 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 355 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 520 kVA
Cooling system: Forced air cooling.
Approx. mass: 260 Kg.
ABB Inverter ACS800-01-0016-3
Product Name: Inverter.
Model: ACS800-01-0016-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 24A.
Frame size: R3.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 7.5KW.
Typical motor power in light-overload use: 11Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.