Home >> Products >> 80
Mitsubishi Digital - analog conversion Module A64DAIC
Model: A64DAIC.
4-channel.
Input (resolution): 4000 -4000, -8000 to 8000, -12 000 to 12000.
Output: DC-10 ~ 10V.
Conversion rate: 25ms / 4 channels.
47-point terminal block.
ABB Inverter ACS550-01-246A-4
Product Name: Inverter.
Model: ACS550-01-246A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 132kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 192A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 246A.
Typical motor power in 400 V at heavy-duty use: 110KW.
Typical motor power in 460 V at heavy-duty use: 150HP.
Typical motor power in 460 V at normal use: 200hp.
Frame size: R6.
ABB Inverter ACS800-01-0040-3
Product Name: Inverter.
Model: ACS800-01-0040-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 72A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 37KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
Typical motor power in light-overload use: 30Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 22KW.
Frame size: R5.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-5
Product Name: Inverter.
Model: ACS800-01-0030-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 42A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 39A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS550-01-059A-4
Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.
Mitsubishi Power supply module A61PEU
Model: A61PEU.
Input: AC100 ~ 120V/AC200 ~ 240V.
Output: DC5V 8A.
Size: 250(H)×55(W)×121(D)mm.
Weight: 0.80kg.
Mitsubishi DC input module AX80E
Model: AX80E.
Input DC: 16 points DC12/24V 4/10mA.
Response time: 6ms/1ms.
8 points per common.
Negative common type.
20-point terminal block.
Size: 250(H)×37.5(W)×121(D)mm.
Weight: 0.39kg.
Mitsubishi Inverter FR-A840-05470-2-60
Product Name: Inverter.
Model: FR-A840-05470-2-60.
220KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity(SLD): 280 kW.
Rated input AC voltage/frequency: Three-phase 380 to 500 V 50 Hz/60 Hz.
Cooling system: Forced air cooling.
Approx. mass: 166 Kg.