Home >> Products >> 97
Mennekes Name:Receptacle strip 96227
Product Name:Receptacle strip
Part No.:96227.
Fitted with:3 CEE 16A, 3p, 110V.
Connection/feeder cable:for 1 cable up to 3 x 10mm2.
Enclosure size:410 x 97 mm (H x W).
Protection type: IP44.
pre-wired for installation.
enclosure grey RAL 7035.
enclosure and insert made of AMAPLAST.
hanging clip enclosed.
Mennekes Cepex flush mounted receptacle SCHUKO 4972
Product Name:Cepex flush mounted receptacle SCHUKO?
Part No.:4972.
Ampere :16A.
Poles:2p.
Voltage:230V.
Earth position:0h.
Hertz:50-60 Hz.
Shutter:no.
Protection type:IP44.
pearl white.
screw terminals.
with flush mounted installation box.
meeting DIN 18032 standards for ball rebound.
ABB Inverter ACS800-01-0050-5
Product Name: Inverter.
Model: ACS800-01-0050-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 65A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 37KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 61A.
Typical motor power in light-overload use: 37Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 30KW.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 50A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0009-5
Product Name: Inverter.
Model: ACS800-01-0009-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 10.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 5.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10A.
Typical motor power in light-overload use: 5.5Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 4KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.56A.
ABB Inverter ACS800-01-0205-3
Product Name: Inverter.
Model: ACS800-01-0205-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 160KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 132KW.
Frame size: R6.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0004-5
Product Name: Inverter.
Model: ACS800-01-0004-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 4.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.5A.
Typical motor power in light-overload use: 2.2Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0011-7
Product Name: Inverter.
Model: ACS800-01-0011-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 13A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 14A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 11.5A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 8.5A.
Typical motor power in heavy-duty use: 5.5KW.
Typical motor power in light-overload use: 7.5Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0050-3
Product Name: Inverter.
Model: ACS800-01-0050-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 86A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
Typical motor power in no-overload use: 45KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 80A.
Frame size: R5.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Typical motor power in heavy-duty use: 30KW.
Typical motor power in light-overload use: 37Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Temperature input Module A1S62RD4
Model: A1S62RD4.
Outline: 2 channels, 4-wire type platinum RTD (Pt100 [JIS C1604-1997, IEC 751-am2, JIS C1604-1989, DIN 43760-1980], JPt100 [JIS C1604-1981]), conversion speed: 40 ms/channel, 20-point terminal block.