Home >> Products >> 99
Mennekes Wall mounted receptacle 599
Product Name:Wall mounted receptacle
Part No.599.
Ampere :32A.
Poles:3P.
Voltage:20-25,40-50V.
Hertz:,100-200 Hz.
Earth position:4 h.
Connection technology:Screw terminals.
Contact:standard.
Protection type:IP44.
screw terminals.
internal fixing.
one cable entry at top and two blind entries (can be cut out) at bottom.
lower part of enclosure base can be turned 180°.
Mennekes Panel mounted receptacle 997
Product Name:Panel mounted receptacle RAPIDO? with TwinCONTACT
Part No.:997.
Ampere:16A.
Poles:3p.
Voltage:230V.
Earth position :6h.
Hertz 50-60Hz.
Connection technology:Screwless - TwinCONTACT.
Contact: standrad.
Protection type IP44.
screwless spring terminals.
suitable for through wiring.
for wall apertures 61 mm ?.
central fixing.
ABB Inverter ACS800-01-0005-5
Product Name: Inverter.
Model: ACS800-01-0005-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 6.2A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Typical motor power in no-overload use: 3KW
Frame size: R2.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.2A.
Typical motor power in heavy-duty use: 2.2KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.6A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-5
Product Name: Inverter.
Model: ACS800-01-0070-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 96A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in heavy-duty use: 45KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 88A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
Typical motor power in no-overload use: 55KW
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0002-2
Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-3
Product Name: Inverter.
Model: ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-3
Product Name: Inverter.
Model: ACS800-01-0006-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 10.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 3KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-3
Product Name: Inverter.
Model: ACS800-01-0025-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 44A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 41A.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 15KW.
Typical motor power in no-overload use: 22KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
114 Results 12/Page Page 5 of 10     << Previous 1 2 3 4 5 6 7 8 9 10 Next >>