Home >> Products >> Mitsubishi >> Q Series PLC >> Q series Communication modules >> Other communication modules
Mitsubishi Load cell input module Q61LD

Model: Q61LD
1 channel.
input (load cell output): 0.0 to 3.3 mV/V.
output (resolution): 0 to 10000.
conversion speed: 10 ms.
18-point terminal block

Mitsubishi Servo external signals interface module Q172LX
Model: Q172LX.
Number of input points: Servo external control signals : 32 points、 8 axes.
Input method: Sink/Source type (Photocoupler).
Rated input: voltage/current 12VDC 2mA、24VDC 4mA.
Exterior dimensions [mm(inch)] : H98(3.86) ? W27.4(1.08) ? D90(3.54).
Weight [kg]: 0.15
Mitsubishi Synchronous encoder interface module Q172EX
Model: Q172EX.
Serial absolute synchronous encoder input: .
Number of modules: 2 per module.
Applicable encoder: MR-HENC.
Position detection method: Absolute (ABS) data method.
Transmission method: Serial communications (2.5Mbps).
Back up battery: A6BAT/MR-BAT..
Tracking enable input: .
Number of input points: 2 points.
Input method: Sink/Source type (Photocoupler).
Rated input voltage/current: 12VDC 2mA、 24VDC 4mA
Mitsubishi Interrupt module QI60
Model: QI60
16 point.
24 V DC.
response time: 0.1/0.2/0.4/0.6/1 ms.
16 points/common.
18-point terminal block
Mitsubishi Loop control module Q62HLC
Model: Q62HLC
2 channels.
input: thermocouple/micro voltage/voltage/current.
conversion speed (input): 25 ms/2 channels.
sampling cycle: 25 ms/2 channels.
output: 4 to 20 mA DC.
conversion speed (output): 25 ms/2 channels; 18-point terminal block.
with 5 PID control modes
Mitsubishi Energy Measuring Module QE81WH
Model: QE81WH
Measurement items (for 1 circuit per module): current.
voltage.
power.
power factor.
frequency.
energy (consumption and regenerative).
Dedicated current sensors are required for operation.
Mitsubishi Synchronous encoder interface module Q172EX-S2
Model: Q172EX-S2.
Serial absolute synchronous encoder input: .
Number of modules: 2 per module.
Applicable encoder: Q170ENC.
Position detection method: Absolute (ABS) data method.
Transmission method: Serial communications (2.5Mbps).
Back up battery: A6BAT/MR-BAT..
Tracking enable input: .
Number of input points: 2 points.
Input method: Sink/Source type (Photocoupler).
Rated input voltage/current: 12VDC 2mA、 24VDC 4mA
Mitsubishi Manual pulse generator interface module Q173PX
Model: Q173PX.
Manual pulse generator/incremental synchronous encoder input: .
Number of modules: 3 per module.
Input frequency: Up to 200kpps (After magnification by 4) ., Tracking enable input: , Number of input points : 3 points.
Input method : Sink/Source type (Photocoupler).
Rated input voltage/current : 12VDC 2mA、 24VDC 4mA
Mitsubishi Dividing unit Q173DV
Model: Q173DV.
For dividing SSCNET lines of Q173CPUN (Attachment: Battery holder for IC-RAM memory backup)
Mitsubishi MES interface Module QJ71MES96
Model: QJ71MES96.
MES interface module *MX MESInterface and CompactFlash card are required.
Mitsubishi High-Speed Data Logger Module QD81DL96
Model: QD81DL96.
High-Speed Data Logger module *CompactFlash card are required
23 Results 12/Page Page 2 of 2     << Previous 1 2