Product Name: Inverter.
Model: ACS800-01-0009-5.
UN = 500 V (Range 380 to ABB ACS800-01-0005-2 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without ABB ACS800-01-0005-2 overloadability at 40 掳C: 10.5A.
Maximum output current. Available for 10 s at start, ABB ACS800-01-0005-2 otherwise as long as allowed by drive temperature. Note: max. Inverter motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 5.5KW
Continuous Inverter current allowing 110% IN for 1 min / 5 min at 40 掳C: 10A.
Typical motor power in light-overload Inverter use: 5.5Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 4KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 7.56A.
Product Name: Inverter.
Model:
ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 掳C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Product Name: Inverter.
Model: ACS800-01-0009-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 25A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 5.5KW
Frame size: R3.
Typical motor power in light-overload use: 5.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 19A.
Typical motor power in heavy-duty use: 4KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 24A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Product Name: Inverter.
Model: ACS800-01-0004-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 掳C: 4.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 4.5A.
Typical motor power in light-overload use: 2.2Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 3.4A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 uunits, ABB ACS800-01-0005-2 H1 is 994 mm, depth 424 mm and weight is 80 kg.
...More Related Model
>>>>