Home >> Products >> 55
ABB Inverter ACS550-01-072A-4
Product Name: Inverter.
Model: ACS550-01-072A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 30KW.
Typical motor power in 400 V at normal use: 37kw.
Typical motor power in 460 V at normal use: 50hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 72A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 40HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 59A.
Frame size: R4.
ABB Inverter ACS550-02-602A-4
Product Name: Inverter.
Model: ACS550-01-602A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Typical motor power in 400 V at normal use: 315kw.
Frame size: R8.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 602A.
Typical motor power in 400 V at heavy-duty use: 280KW.
Typical motor power in 460 V at heavy-duty use: 450HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 515A.
Typical motor power in 460 V at normal use: 500hp.
ABB Inverter ACS355-03X-31A0-2
Product Name: Inverter.
Model: ACS355-03X-31A0-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 7.5kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31.0A.
Frame size: R4.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 10.0hp.
ABB Inverter ACS355-03X-03A3-4
Product Name: Inverter.
Model: ACS355-03X-03A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 1.1kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 1.5hp.
ABB Inverter ACS355-03X-31A0-4
Product Name: Inverter.
Model: ACS355-03X-31A0-4.
This code states the factory installed SW variants to the drive.
Typical motor power in 400 V at normal use: 15.0kw.
Typical motor power in 460 V at normal use: 20.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31.0A.
Frame size: R4.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
3-phase AC supply, 380 to 480 V.
ABB Inverter ACS800-01-0002-2
Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-3
Product Name: Inverter.
Model: ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-3
Product Name: Inverter.
Model: ACS800-01-0006-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 10.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 3KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-5
Product Name: Inverter.
Model: ACS800-01-0070-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 96A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in heavy-duty use: 45KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 88A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
Typical motor power in no-overload use: 55KW
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
611 Results 12/Page Page 21 of 51     [First Page] << Previous 17 18 19 20 21 22 23 24 25 26 Next >> [Last Page]