Home >> Products >> 94
Mennekes AMAXX receptacle combination 940026
Product Name:AMAXX? receptacle combination
Part No.:940026.
Fitted with:1 CEE 32A, 4p, 400V
2 CEE 16A, 4p, 400V
2 french/belg. standard 16A, 2p+E, 230V.
Fusing:1 RCD 63A, 4p, 0.03A
1 MCB 32A, 3p, C
2 MCB′s 16A, 3p, C
2 MCB′s 16A, 1p+N, C.
Pre-fuse max.:63A.
InA:44A.
RDF:0.55.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
ABB Inverter ACS800-01-0030-5
Product Name: Inverter.
Model: ACS800-01-0030-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 42A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 39A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0100-7
Product Name: Inverter.
Model: ACS800-01-0100-7.
Frame size: R6.
Rated current available continuously without overloadability at 40 °C: 93A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 124A.
Typical motor power in no-overload use: 90KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 86A.
Typical motor power in light-overload use: 75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 62A.
Typical motor power in heavy-duty use: 55KW.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes AMAXX receptacle combination 940215
Product Name:AMAXX? receptacle combination
Part No.:940215.
Fitted with:1 CEE 32A, 5p, 400V
1 CEE 16A, 5p, 400V
2 swiss standard type 25, 16A, 5p, 400V
2 swiss standard type 23, 16A, 3p, 230V.
Fusing:1 RCD 63A, 4p, 0.03A
1 MCB 32A, 3p, C
1 MCB′s 16A, 3p, C
1 MCB′s 16A, 1p, C
Pre-fuse max.:63A.
InA:45A.
RDF:0.35.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
Mennekes AMAXX receptacle combination 940013
Product Name:AMAXX? receptacle combination
Part No.:940013.
Fitted with:2 CEE 16A, 5p, 400V
2 SCHUKO? 16A, 230V.
Fusing:1 RCD 40A, 4p, 0.03A
2 MCB′s 16A, 3p, C
2 MCB′s 16A, 1p, C.
Pre-fuse max:40A.
InA :36A.
RDF:0.75.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP67.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
Mennekes AMAXX receptacle combination 940016
Product Name:AMAXX? receptacle combination
Part No.:940016.
Fitted with:1 CEE 32A, 5p, 400V
1 CEE 16A, 5p, 400V
2 SCHUKO? 16A, 230V.
Fusing:1 RCD 63A, 4p, 0.03A
1 MCB 32A, 3p, C
1 MCB 16A, 3p, C
2 MCB′s 16A, 1p, C.
Pre-fuse max:100A.
InA :44.8A.
RDF:0.7.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225mm (H x W).
Protection type IP67.
highly resistant to chemicals made of AMELAN?.
with highly heat resistant contact carrier and nickel plated contacts.
pre-wired for installation.
enclosure front cover grey RAL 7000.
hinged to the side.
fusing behind a transparent cover.
Mennekes Wall mounted receptacle 7886
Product Name:Wall mounted receptacle
Part No.7886.
Ampere:125A.
Poles:5P.
Voltage:400V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology :Screw terminals.
Contact:standard.
screw terminals.
all-pole ON/OFF switching by turning the plug.
identification acc. to 94/9/EG: II 3D Ex tD A22 T80°C.
dust ignition protection type provided: Ex de IIC T6.
cable entry 1x Ex-cable gland and 1x Ex-screw plug made of plastic at bottom.
enclosure: glass-fibe reinforced polyester.
permissible ambient temperature: -25°C to +45°C.
ABB Inverter ACS800-01-0020-3
Product Name: Inverter.
Model: ACS800-01-0020-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 34A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 15KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
Typical motor power in heavy-duty use: 11KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-5
Product Name: Inverter.
Model: ACS800-01-0006-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 8.1A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.6A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 3KW.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0205-5
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes AMAXX receptacle combination 940744
Product Name:AMAXX? receptacle combination
Part No.:940744.
Fitted with:1 CEE 16A, 5p, 400V
2 french/belg. standard 16A, 2p+E, 230V
1 CEE 16A, 2p, 20-25V.
Fusing:1 RCD 40A, 4p, 0.03A
1 MCB 16A, 3p+N, C
1 MCB 16A, 1p+N, C
1 single phase transformer 160VA, 230V/24V
1 MCB 6A, 2p, C
1 MCB 4A, 1p+N, C.
Pre-fuse max:100A.
InA :26A.
RDF:0.6.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
150 Results 12/Page Page 3 of 13     << Previous 1 2 3 4 5 6 7 8 9 10 Next >> [Last Page]