Product Name: Inverter.
Model: ACS800-01-0004-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 6.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.9A.
Typical motor power in light-overload use: 2.2Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 1.3A.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Product Name: Inverter.
Model: ACS800-01-0009-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 13.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
Typical motor power in no-overload use: 5.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.
Typical motor power in light-overload use: 5.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.
Typical motor power in heavy-duty use: 4KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.