Home >> Products >> ABB >> Inverter >> ACS800 Inverter >> ACS800-01-0030-7 690 V Range 525 to 690 V The power ratings are valid at nominal voltage 690 V ABB ACS800-01-0030-7

ACS800-01-0030-7 690 V Range 525 to 690 V The power ratings are valid at nominal voltage 690 V ABB ACS800-01-0030-7

Product Name: Inverter.
Model: ACS800-01-0030-7 ACS800-01-0030-7.
UN = 690 V (Range 525 to 690 V). The power ACS800-01-0030-7 ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 33A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 44A.
Typical motor power in no-overload use: 30KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 30A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 22A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

ABB ACS800-01-0030-7
Product Name: Inverter.
Model: ACS800-01-0004-5.
UN = 500 V (Range 380 ABB ACS800-01-0030-7 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without ABB ACS800-01-0030-7 overloadability at 40 °C: 4.9A.
Maximum output current. Available for 10 s at ABB ACS800-01-0030-7 start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.5A.
Typical motor power in light-overload use: 2.2Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.


Product Name: Inverter.

Model: ACS800-01-0009-3.

UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.

Rated current available continuously without overloadability at 40 °C: 13.9A.

Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.

Typical motor power in no-overload use: 5.5KW

Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.

Typical motor power in light-overload use: 5.5Kw.

Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.

Typical motor power in heavy-duty use: 4KW.

Frame size: R2.

ACS800-01 without cable connection box does not ful? ll IP21 requirements.

In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.

In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.




Product Name: Inverter.
Model: ACS800-01-0040-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 103A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in no-overload use: 30KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 94A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
Typical motor power in heavy-duty use: 18.5KW.
Frame size: R5.
Typical motor power in light-overload use: 22Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0070-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 96A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in heavy-duty use: 45KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 88A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
Typical motor power in no-overload use: 55KW
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 uniits, ACS800-01-0030-7 H1 is 994 mm, depth 424 mm and weight is 80 kg.





...More Related Model >>>>
Related Download
Related Models