ABB Inverter ACS550-01-03A3-4
Product Name: Inverter.
Model: ACS550-01-03A3-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 1.5hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 3.3A.
Typical motor power in 400 V at heavy-duty use: 0.75KW.
Typical motor power in 460 V at heavy-duty use: 1HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Typical motor power in 400 V at normal use: 1.1kw.
ABB Inverter ACS550-01-04A1-4
Product Name: Inverter.
Model: ACS550-01-04A1-4.
Typical motor power in 400 V at heavy-duty use: 1.1KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 1.5kw.
Typical motor power in 460 V at normal use: 2hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 4.1A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 1.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
Frame size: R1.
ABB Inverter ACS550-01-015A-4
Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 15.4A.
ABB Inverter ACS550-01-246A-4
Product Name: Inverter.
Model: ACS550-01-246A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 132kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 192A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 246A.
Typical motor power in 400 V at heavy-duty use: 110KW.
Typical motor power in 460 V at heavy-duty use: 150HP.
Typical motor power in 460 V at normal use: 200hp.
Frame size: R6.
ABB Inverter ACS550-01-059A-4
Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.
ABB Inverter ACS550-01-038A-4
Product Name: Inverter.
Model: ACS550-01-038A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 15KW.
Typical motor power in 400 V at normal use: 18.5kw.
Typical motor power in 460 V at normal use: 25hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 38A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 20HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31A.
Frame size: R3.
ABB Inverter ACS550-01-045A-4
Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.
ABB Inverter ACS550-01-087A-4
Product Name: Inverter.
Model: ACS550-01-087A-4.
Frame size: R4.
Wall-mounted units.
Typical motor power in 400 V at normal use: 45kw.
Typical motor power in 460 V at normal use: 60hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 87A.
Typical motor power in 400 V at heavy-duty use: 37KW.
Typical motor power in 460 V at heavy-duty use: 60HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 72A.
3-phase supply voltage 380 to 480 V.
ABB Inverter ACS550-01-012A-4
Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.
ABB Inverter ACS550-01-031A-4
Product Name: Inverter.
Model: ACS550-01-031A-4.
Frame size: R3.
Wall-mounted units.
Typical motor power in 400 V at normal use: 15kw.
Typical motor power in 460 V at normal use: 20hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 31A.
Typical motor power in 400 V at heavy-duty use: 11KW.
Typical motor power in 460 V at heavy-duty use: 15HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 23A.
3-phase supply voltage 380 to 480 V.
ABB Inverter ACS550-01-023A-4
Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.
ABB Inverter ACS550-01-05A4-4
Product Name: Inverter.
Model: ACS550-01-05A4-4.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3hp.
Wall-mounted units.
Typical motor power in 400 V at heavy-duty use: 1.5KW.
Typical motor power in 460 V at heavy-duty use: 2HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.