ABB Inverter ACS550-01-06A9-4
Product Name: Inverter.
Model: ACS550-01-06A9-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 6.9A.
Typical motor power in 400 V at heavy-duty use: 2.2KW.
Typical motor power in 460 V at heavy-duty use: 3HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 3kw.
ABB Inverter ACS550-01-08A8-4
Product Name: Inverter.
Model: ACS550-01-08A8-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 6.9A
Typical motor power in 460 V at normal use: 5.4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 8.8A.
Typical motor power in 400 V at heavy-duty use: 3KW.
Typical motor power in 460 V at heavy-duty use: 4HP.
Typical motor power in 400 V at normal use: 4kw..
Frame size: R1.
ABB Inverter ACS550-01-012A-4
Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.
ABB Inverter ACS550-01-015A-4
Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 15.4A.
ABB Inverter ACS550-01-023A-4
Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.
ABB Inverter ACS550-01-031A-4
Product Name: Inverter.
Model: ACS550-01-031A-4.
Frame size: R3.
Wall-mounted units.
Typical motor power in 400 V at normal use: 15kw.
Typical motor power in 460 V at normal use: 20hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 31A.
Typical motor power in 400 V at heavy-duty use: 11KW.
Typical motor power in 460 V at heavy-duty use: 15HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 23A.
3-phase supply voltage 380 to 480 V.
ABB Inverter ACS550-01-038A-4
Product Name: Inverter.
Model: ACS550-01-038A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 15KW.
Typical motor power in 400 V at normal use: 18.5kw.
Typical motor power in 460 V at normal use: 25hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 38A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 20HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31A.
Frame size: R3.
ABB Inverter ACS550-01-045A-4
Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.
ABB Inverter ACS550-01-059A-4
Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.
ABB Inverter ACS550-01-072A-4
Product Name: Inverter.
Model: ACS550-01-072A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 30KW.
Typical motor power in 400 V at normal use: 37kw.
Typical motor power in 460 V at normal use: 50hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 72A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 40HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 59A.
Frame size: R4.
ABB Inverter ACS550-01-087A-4
Product Name: Inverter.
Model: ACS550-01-087A-4.
Frame size: R4.
Wall-mounted units.
Typical motor power in 400 V at normal use: 45kw.
Typical motor power in 460 V at normal use: 60hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 87A.
Typical motor power in 400 V at heavy-duty use: 37KW.
Typical motor power in 460 V at heavy-duty use: 60HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 72A.
3-phase supply voltage 380 to 480 V.
ABB Inverter ACS550-01-125A-4
Product Name: Inverter.
Model: ACS550-01-125A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 55kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 96A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 125A.
Typical motor power in 400 V at heavy-duty use: 45KW.
Typical motor power in 460 V at heavy-duty use: 75HP.
Typical motor power in 460 V at normal use: 100hp.
Frame size: R5.